Hospital Grade UPS specifications and product information
|
| catalog number: |
329-T045E |
329-T070E |
329-T140E |
| output capacity: |
450 VA / 280 watts |
700 VA / 425 watts |
1400 VA / 940 watts |
| run time -half load: |
17 minutes |
22 minutes |
24 minutes |
| run time -full load: |
5 minutes |
9 minutes |
8 minutes |
| output regulation: |
120 volts ±5% (while running on battery power) |
| frequency regulation: |
60Hz ± 0.5Hz on battery power |
| output waveform: |
modified sine wave - pulse width modulated |
| input voltage rating: |
120 volts 60Hz nominal |
| leakage current: |
less than 300 µa |
| maximum input current: |
2.8 amps / 320 watts |
3.8 amps / 460 watts |
8.25 amps / 990 watts |
| line voltage regulation: |
120 volts 18% / +8% |
120 volts 18% / +8% |
120 volts 18% / +8% |
| transfer time: |
2-4 ms |
2-4 ms |
2-4 ms |
| transfer to battery: |
75 volts, 147 volts |
75 volts, 147 volts |
75 volts, 147 volts |
| transfer to line power: |
79 volts, 143 volts |
79 volts, 143 volts |
79 volts, 143 volts |
| battery voltage: |
12 volts |
12 volts |
36 volts |
| battery recharge time: |
90% of battery capacity in 2-4 hours |
| typical battery life: |
4 to 6 years depending on use |
| power cord: |
6 ft 14AWG with NEMA 5-15PHG Hospital Grade plug |
| receptacles: |
4 (NEMA 5-15RHG Hospital Grade duplex receptacles) |
| line below 75 volts: |
transfer to battery power |
| line 75 to 92 volts: |
line voltage boosted by 30% at output |
| line 93 to 107 volts: |
line voltage boosted by 14% at output |
| line 108 to 127 volts: |
line voltage passed unchanged to output |
| line 128-147 volts: |
line voltage reduced by 12% at output |
| line above 148 volts: |
transfer to battery power |
| communications: |
basic DB9 monitoring port |
| surge suppression: |
conforms to IEEE 587 / ANSI C62.41 specs |
| EMI/RFI suppression: |
yes |
yes |
yes |
| weight: |
21 lbs, 9.5 kg |
22 lbs, 10 kg |
37 lbs, 16.8 kg |
| dimensions (in): |
10.75 x 5.25 x 7.25 |
10.75 x 5.25 x 7.25 |
12.5 x 7.5 x 9 |
| dimensions (cm): |
27.3 x 13.3 x 18.4 |
27.3 x 13.3 x 18.4 |
31.75 x 19.1 x 22.7 |
| coo9ling method: |
convection |
| operating temperature: |
+32º F to +104º F, 0º C to +40º C |
| storage temperature: |
+5º F to +122º F, 15º C to +50º C |
| relative humidity: |
0 to 95% non-condensing |
| Manufacturer: |
Tripp Lite |
| OEM Model: |
OMNISMART450HG |
OMNISMART700HG |
OMNISMART1400HG |
| FCC (emissions): |
Class A |
Class A |
Class A |
| listings: |
UL 1778 |
| warranty: |
2 years |
features: |
- Low leakage current and hospital grade plug connections
- Line interactive voltage regulation corrects brownouts
- Complete surge protection and EMI/RFI noise filtering
- DB9 serial port for network interface; SNMP compatible
- Cold start capability allows turn-on during blackouts
- Battery replacement door
- 5 diagnostic LEDs indicate:
- AC line current present
- running on battery power
- voltage correction active
- overload condition present
- battery low or needs replacement
|
typical applications: |
- Nurse's stations
- Mobile medical record systems
- Medical and dental offices
- Laboratories
- Medical imaging and laboratory equipment
- Wireless communications systems
- Where low leakage and hospital grade connections are needed
|