Siemens Atellica 1500 Automated Urinalysis System
Please sign in so that we can notify you about a reply
Description
Combining the CLINITEK Novus Analyzer and the new Atellica® UAS 800 Analyzer* into one completely automated unit, the Atellica 1500 Automated Urinalysis System* sets the new standard for accuracy and efficiency. It is a truly digital automated urinalysis system and lets you manage more samples with less staff in a shorter time, while never compromising on high-quality results.
- Combines 2 advanced analyzers, the trusted CLINITEK Novus Analyzer, and the new Atellica UAS 800 Analyzer
 - The CLINITEK Novus Analyzer combines trusted urine strip technology with cutting-edge digital imaging to deliver consistent, high-quality results
 - The new Atellica UAS 800 Analyzer is a completely automated urine sediment analyzer designed to minimize the need for manual microscopy
 - Urine chemistry and sediment technologies streamline the detection of UTIs and early kidney disease.
 
Features of Siemens Atellica 1500 Automated Urinalysis System:
The System
Atellica 1500 Automated Urinalysis System
The Atellica 1500 Automated Urinalysis System* lets you manage more samples with less staff in a shorter time, while never compromising on high-quality results.
- Measurement technology: Digital microscopy imaging with a dual-focusing mechanism to generate clear images
 - Combines dry-pad urine chemistry and powerful digital microscopy into a single, streamlined unit
 - Throughput range: Up to 240 samples per hour
 - Streamlines the detection of UTIs and early kidney disease for better clinical outcomes.
 
The Analyzers
CLINITEK Novus Automated Urine Chemistry Analyzer
- Digital Camera Module: LED and colored CCD camera that captures full RGB color spectrum to calculate color changes for each parameter, instead of a 3-4 fixed wavelength
 - Optical Sensors: Refractometry method that calculates clarity and specifies gravity.
 
Atellica UAS 800 Urine Sediment Analyzer
- Minimal consumables: Only cuvettes are needed – no liquid reagents with consumable exchanging taking less than 3 minutes
 
Specification of Siemens Atellica 1500 Automated Urinalysis System:
CLINITEK Novus 10 Cassette      | CLINITEK Novus PRO 12 Cassette*  | Auto-reported Categories  | 
Bilirubin  | Albumin  | Bacteria  | 
Clarity  | Albumin-to-creatine ratio  | Crystals  | 
Color  | Bilirubin  | Hyaline cast  | 
Glucose  | Clarity  | Mucus  | 
Ketone  | Color  | Nonsquamous EC  | 
Leukocyte esterase  | Creatine  | Pathalogical cast  | 
Nitrite  | Glucose  | RBC  | 
Occult blood  | Ketone  | Sperm  | 
pH  | Leukocyte esterase  | Squamous EC  | 
Protein  | Nitrite  | WBC  | 
Specific gravity  | Occult blood  | Yeast  | 
Urobilinogen  | pH  | Sub-categories:  | 
  | Protein  | Bacteria cocci  | 
  | Protein-to-creatine ratio  | Bacteria rods  | 
  | Specific gravity Urobilinogen  | WBC clumps  | 
Technical Details
Physical Information  | |
Depth (with rack handler)  | 680 mm  | 
Height (with rack handler)  | 625 mm  | 
Width (with rack handler)  | 1260 mm  | 
Weight  | 114 kg  | 
System Information  | |
Throughput  | 106–240 samples/hr  | 
Storage  | 10,000 patient results including images  | 
Decibel rating  | < 60 dB  | 
STAT function  | Yes  | 
Sediment Result units  | cells/μl, cells/hpf, cells/lpf  | 
Chemistry Result units  | Conventional, Conventional with plus system, SI, and SI with plus system  | 
Time to first result  | < 4 minutes  | 
Sample loading capacity  | 100 samples  | 
Interface  | TCP/IP or Serial - ASTM and HL7  | 
Sediment Menu  | |
• RBC (red blood cell)  | • NEC (nonsquamous epithelial cell)  | 
Chemistry Menu  | |
CLINITEK Novus Analyzer with CLINITEK Novus Cassettes  | |
CLINITEK Novus 10 Cassette 
 
  | CLINITEK Novus PRO 12 Cassette†  | 
Electrical Requirements  | |
Main unit  | 110–240 VAC | 50–60 Hz | 210 W max.  | 
Personal computer with WINDOWS 7 operating system  | 100–240 VAC | 50–60 Hz | 400 W max.  | 
Monitor  | 100–240 VAC | 50–60 Hz | 100 W max.  | 
Environmental Specifications  | |
Operating temperature  | 18–30°C (64–86°F)  | 
Operating humidity  | 20–80% RH, noncondensing  | 
Altitude range of operation  | 0–2000 m above sea level  | 
Storage temperature  | -25 to +60°C (-13 to +140°F)  | 
Storage humidity  | 20–80% RH , noncondensing  | 
Storage atmospheric pressure  | 106–70kPA (approximately 0–3000 m)  | 
Compliance  | TUV, CE, EMC, IEC 61326  | 
Supported Bar-code Specifications  | |
Supported bar-code types†  | Codabar  | 
Test Rack and Tube Specifications  | |
Test tube racks supported  | Only test tube racks provided by Siemens Healthineers  | 
Minimum sample volume in tube  | 2.6 mL  | 
Height  | 95–106 mm (3.74–4.17 inches)  | 
Rack opening diameter  | 16.5 mm (0.64 inches)  | 
Cuvettes  | |
Supported types  | Only Atellica UAS 800 cuvette cartridges supplied by Siemens Healthineers  | 
Number of tests per cartridge  | 600 cuvettes  | 
Shelf life  | 2 years  | 
Test Cassettes  | |
Supported types  | CLINITEK Novus 10 Cassette  | 
Features
- 1 Year
 - From manufacturer
 
Product Specifications
Brand/Manufacturer
Weight & Dimensions