The Philips BiPAP A40 is a non-invasive hospital-grade BiPAP ventilator used to support patients with chronic respiratory conditions such as sleep apnea, asthma, and respiratory acidosis. This bi level ventilator offers efficient and adaptable breathing support for patients in home care, hospitals, and respiratory therapy centers.
The Philips BiPAP A40 seamlessly integrates into long-term ventilation care with advanced modes, such as AVAPS-AE, that automatically adjust therapy to match the patient's breathing needs, even during sleep or positional changes. It can deliver both low-pressure support for lighter breathing needs and high-pressure settings up to 40 cmH₂O for patients with more severe respiratory insufficiency, ensuring a wide range of clinical applications.
Thanks to its compact design and built-in battery module, the BiPAP A40 supports up to 5 hours of continuous operation, making it ideal for both stationary and mobile use. It also features a heated humidifier with Dry Box technology, which reduces rainout and ensures consistent humidity control during therapy.
Along with this, the BiPAP A40 ventilator offers seamless data connectivity through DirectView and EncorePro, allowing clinicians to monitor and optimize therapy with detailed reports and up to one year of stored data, including SpO₂ readings and waveform tracking.
Key Features of Philips A40 BiPAP:
- AVAPS ventilation automatically adjusts the pressure support to help you reduce your patient’s PaCO₂ levels, so you don’t have to make constant manual changes.
- Automated Airway Management lets you treat both OSA and hypoventilation together in any mode, so you can manage overlapping conditions without switching devices.
- AVAPS-AE has been shown to reduce nocturnal hypoventilation and upper airway obstruction while improving sleep quality, making it easier for your patients to stick to therapy.
- Visual leak management gives you a clear, color-coded view of total circuit leaks, so you can adjust the mask or setup quickly for better comfort and consistent therapy.
Benefits of Philips A40 BiPAP:
- Stable breathing all night long: The BiPAP A40 helps your patient maintain a consistent breathing pattern, reducing sleep disruptions caused by apnea or other respiratory issues.
- More energy in the daytime: By improving sleep quality, it helps reduce fatigue and sleepiness, so your patient can stay active and alert during the day.
- Less effort, better breathing: With dual pressure support (IPAP and EPAP), it keeps the airways open, improves oxygen flow, and eases the work of breathing for more relaxed therapy.
- Pressure that adapts to your patient: Smart features like AVAPS-AE and Auto-TRAK automatically adjust pressure levels based on real-time needs, keeping therapy both effective and comfortable.
- Comfortable therapy with humidity: It's built-in humidifier prevents a dry nose and throat, especially useful in dry climates or with extended use.
- Take therapy anywhere: Lightweight and portable with optional battery backup, it gives patients reliable ventilation whether they’re at home or on the move.
- Track progress with confidence: It stores therapy data and syncs with software like DirectView, so you can easily monitor results and fine-tune settings when needed.
- Keep patients out of the hospital: By delivering consistent support at home, it helps prevent complications that could lead to hospital readmissions.
Technical Specifications of Philips A40 BiPAP:
IPAP/EPAP | 4 - 30 cm H2O / 4-25 cm H2O |
Ventilation modes: | CPAP, S, S/T, PC, T, AVAPS-AE, |
Target tidal volume: | 200 - 1500 ML |
Breath rate: | 0 - 40 bpm |
Rise time: | 1(100ms) - 6 (600ms) |
Humidification: | System One humidity control and ‘Dry Box’ technology |
Hybrid ventilation: | AVAPS (Average Volume Assured Pressure Support) |
AVAPS rate: | 0.5 to 5 cm H2O/min |
Inspiratory time: | 0.5 to 3 sec |
Alarms: | Patient disconnection, apnea, low minute ventilation, low tidal volume, high respiratory rate |
Monitoring: | Pressure, tidal volume, minute ventilation, respiration rate, leak |
Filters: | Foam and optional ultra-fine |
Data Management: | EncorePro 2 and DirectView software Compatible with oximetry module, Advanced detection of residual respiratory events (Apnea/Hypopnea Index, Obstructed Airway Apnea, Clear Airway Apnea, Hypopnea, Periodic Breathing, RERA, Large Leak, and Snore) |
DC power source: | 12VDC, 5.0 A |
External battery: | 24VDC, 4.2 A |
Battery backup: | 11 hours at IPAP 15 / EPAP 4 cm H2O and 12 BPM |
Noise level: | 30 dBa AT 10 cm of water |
IPAP: EPAP: | 4-40cm H2O 4-25 cm H2O |
What is in the Box?
- Device
- filters
- tubing
- power cord
- User manual SD card
FAQs About Philips A40 BiPAP:
What therapy does the Philips A40 BiPAP ventilator provide?
It delivers both non-invasive and invasive pressure ventilation (up to 40 cmH₂O), supporting a broad range of patient needs
What conditions can the Philips A40 BiPAP ventilator treat?
It’s intended for adults and children over 10 kg with OSA, respiratory insufficiency, or respiratory failure.
What should clinicians know about Philips A40 BiPAP ventilator battery alarms?
It has a two-stage low-battery alarm, around 20 minutes left for medium priority and under 10 minutes for high priority.
What safety alert should be expected with the Philips A40 BiPAP ventilator?
Clinicians must watch for the Ventilator Inoperative alarm, which may indicate therapy stops or unexpected reboots.
What usage environments are supported by the Philips A40 BiPAP ventilator?
It’s designed for home, hospital, sleep lab, and portable settings, but it’s not marketed as a life-support or transport ventilator.
What staff qualifications are required to operate the Philips A40 BiPAP ventilator?
It must be used by trained respiratory or clinical caregivers and under physician supervision.
What maintenance issues should users be aware of on the Philips A40 BiPAP ventilator?
Avoid harsh detergents or ozone cleaners use only approved cleaning methods to prevent damage
What should clinicians do if the Philips A40 BiPAP ventilator’s "High Internal Oxygen" alarm activates?
Continue therapy (device remains functional) and follow Philips' guidance to verify alarm status and ensure patient safety.
More BiPAP Machines from Philips:
Here are a comparison of Philips BiPAP Machine:
Specifications | |||
Ventilation modes | CPAP • S • S/T • PC • T • AVAPS-AE | Auto BiPAP, Fixed BiPAP, and Fixed CPAP | Digital Auto-Trak and AVAPS |
Noise level | < 28 dBA at 10cmH2O | 25.8 dBA | 26 dB(A) ±2 dB |
Breath rate | 0 – 40 bpm (4 – 40 bpm in T mode) | 4 to 30 breaths per minute | 1 to 30 (increment is 1 breath) |
Display Type/Size | 11.5 cm | full-color LCD screen | color LCD screen with a control dial/push-button |
Dimensions | 22.23 cm W x 18.42 cm L x 10.80 cm H | 15,7 (L) x 19,3 (W) x 8,4 cm (H) | 15.7 x 19.3 x 8.4 cm (w/o humidifier) |
Weight | 1.9 kgs | 1,33 kg (without humidifier), 1,98 kg(with humidifier) | 1.33 kg/2.94 lbs |
Power Supply Unit | AC Input: 100–240 VAC, 50/60 Hz, 1.2 A (max) | Input: 100–240 VAC, 50/60 Hz Output: 12 V DC @ 6.67 A | Input: 100–240 VAC, 50/60 Hz Output: 12 V DC @ 6.67 A, rated for humidifier and heated tubing |
Similar Products:
Specifications | Philips A40 | |||
Ventilation modes | CPAP • S • S/T • PC • T • AVAPS-AE | CPAP • S • S/T • PC • T • AVAPS-AE | CPAP, S, ST, T | S, ST, T |
Noise level | < 28 dBA at 10cmH2O | < 28 dBA at 10cmH2O | 26.6 dBA | Less than 30 dBA |
Breath rate | 0 – 40 bpm (4 – 40 bpm in T mode) | 0 – 40 bpm (4 – 40 bpm in T mode) | Not Specified | Adjustable from 3 to 30 breaths per minute |
Display Type/Size | 11.5 cm | 11.5 cm | 2.4-inch color LCD display | 2.8-inch color LCD screen |
Dimensions | 22.23 cm W x 18.42 cm L x 10.80 cm H | 22.23 cm W x 18.42 cm L x 10.80 cm H | 11 mm X 205 mm X 150 mm & 116 mm X 255 mm X 150 mm (With Humidifier) | Approx. 290 mm × 196 mm × 134 mm |
Weight | 1.9 kgs | 1.9 kgs | 1106 g & 1268 g (With Humidifier) | Around 1.5 kg (without humidifier) |
Power Supply Unit | AC Input: 100–240 VAC, 50/60 Hz, 1.2 A (max) | AC Input: 100–240 VAC, 50/60 Hz, 1.2 A (max) | Input Range: 100240V, 5060 Hz, 57VA (Typical Power Consumption) & 108VA (Peak Power Consumption) | AC input: 100–240V, 50/60Hz DC output: 24V |
Features
- From Manufatcurer
- 1 Years
Product Specifications
- High
Brand/Manufacturer
Weight & Dimensions
Power Supply & Battery
Reviews
No reviews found
Review this product
Share your thoughts with other customers