Product filters
Price

 – 

  • ‎₹0
  • ‎₹0
Stock
Shipping

Boyles Apparatus

Introduction to Boyles Apparatus:

Dr. Henry Boyle developed the Boyle's Apparatus in 1917. It was designed to mix gases within a glass chamber using a tube and water system that creates bubbles to measure gas flow.

This machine is an essential component of the anesthesia machine, playing a crucial role and remaining in use for more than five decades. 

With the rise in anesthetic drug use around 1955, the Boyle machine gained widespread popularity. The original setup included a flow meter, vaporizer, and a breathing bag, enabling precise delivery of anesthesia gases to patients. 

Uses of Boyles Apparatus:

General Anesthesia: The main use of Boyles Apparatus is to deliver anesthetic gases to patients who have lost consciousness during surgery.

Oxygen Therapy: One of the important uses of Boyles Apparatus is to provide a high concentration of oxygen to patients suffering from respiratory issues.

Support for Ventilation: Boyles Apparatus can assist or control a patient’s breathing during medical procedures, making it vital in critical care.

Inhalation Sedation: It is used to administer inhalable anesthetic agents like sevoflurane and desflurane to keep the patient calm and pain-free.

Pediatric Anesthesia: Due to the unique physiology of children, specialized pediatric anesthetics can be safely delivered using Boyles Apparatus.

Parts of Boyles Apparatus:

Gas Supply System: The Boyles Apparatus is composed of a gas supply system that includes gas cylinders, pipeline inlets, pressure gauges and regulators to allow for a reliable supply of gas to hospitals.

Flow Meters: Each individual gas has its own flow meter so flow rates of gas can be managed as accurately as possible, which is one of the primary applications of the Boyles Apparatus.

Vaporizers: The vaporizer element is used to administer volatile anaesthetic agents. Vaporizers are agent-specific and temperature-compensated.

Breathing Circuit: Contains the inspiratory and expiratory valves, a reservoir bag for the patient to rebreathe out of and a CO₂ absorber geared for the rebreathing systems.

Ventilator: Mechanically ventilates a patient to support general anaesthesia, which is one of the primary applications of the Boyles Apparatus in surgical contexts.

Scavenging System: Collects and removes waste anaesthetic gases, improving safety and the working environment of the operating room.

Monitoring Devices: Includes oxygen analyzers, capnographs (to monitor CO₂), pressure gauges, and alarms to monitor gas flow and ensure patient safety.

How Boyles Apparatus Works:

Gas Supply Control: The Boyles Apparatus connects to sources of medical gas like nitrous oxide and oxygen.

Flowmeter Function: It utilizes flowmeters to control and measure the amount of gas that reaches the patient.

Vaporizer Role: Vaporizer changes the liquid anesthetic agents (halothane, isoflurane, etc.) to vapors.

Gas Mixing: The vapors (anesthetic) are mixed with oxygen or other gases in appropriate proportions.

Delivery to Patient: The gas is delivered to the patient through the breathing circuit.

Breathing Bag Support: A reservoir (breathing) bag is the storage container for the gas and also allows for use of ventilating if needed.

Safety Features: Includes pressure gauges, alarms, and safety valves that aid in monitoring and preventing accidents, such as low oxygen levels.

Continuous Monitoring: The machine maintains a continuous, safe supply of anesthesia to the patient throughout surgery in order to keep the patient unconscious and free from pain.

The Vital Role of Boyles Apparatus for Clinics/Hospitals:

Safe Anesthesia Delivery: A Boyles Apparatus allows for the effective control of anesthetic gases during procedures, thereby keeping the patient safe while they are incapacitated from medications.

Flexibility: One of the most significant benefits of a Boyles Apparatus is the capability to allow anesthetic gas delivery appropriate for numerous types of anesthesia in multiple specialties.

Standardization: Due to the large scale utilization of the Boyles Apparatus, there has been standardization in the delivery of anesthetic agents across healthcare faculty.

Customization: A Boyles Apparatus was built in a fashion to allow some flexibility for updates, which can include adding or removing anesthetic agents, as well as updated and new safety measures.

Economical: One of the most wanted features of a Boyles Apparatus is how it is known for its robustness and reliability, making it a sound financial and long-term investment for any hospital or clinic.

Patient Monitoring: The above mentioned, the "Boyle Bottle" can be used by healthcare providers to visualize and gain insight and assessment of gas flow rates that occur during procedures.

Understand the Boyles Apparatus Price:

This is the most common question doctors ask our team when exploring our Boyles apparatus: What is the price of the Boyles apparatus? 

And we reply simply, the price varies depending on the models. In India, the starting price of the Boyles apparatus starts from ₹12,500 and it goes up to ₹1,45,000.

Where to Buy Boyle Apparatus Online?

If you want to buy the best Boyles machine online in India, you find there are too many E-commerce platforms, but no one like Biomed Suppliers. We are the one-stop solution for Boyles machine and other medical equipment for various medical facility. 

We provide a flexibility in payment allows you to manage your finances more comfortably. As you can pay a token amount online when placing your order, and the rest of the payment can be settled using Cash on Delivery (COD).

Essential Points to Note Before Buying Boyles Apparatus:                                            

Compatibility: 

Before purchasing any Boyles Apparatus, ensure it's compatible with your hospital's gas supply lines and existing equipment.

Regulatory Compliance:

Make sure the apparatus is compliant with current medical safety standards and in accordance with local laws and regulations.

Ease of Maintenance:

Google how often you need to maintain your Boyles Apparatus and ease of maintenance in serviceability terms (cost and ability).

Stability:

Buy Boyles Apparatus that meets your current needs while also being adaptable for future technological change.

Energy Efficient: 

Consider both the apparatus's energy consumption and environmental footprint.

Cost-effective: 

Buy the Boyles Apparatus that strikes the right balance between your initial outlay and operating costs.

Safety Features of Boyles Apparatus:

1. Pin Indexing and Color Coding: 

The Boyles Apparatus utilizes pin indexing and color coding to safely, and properly connect the gas cylinders. These features assist in quickly identifying which gases are being used, thus maintaining a certain level of safety.

2. Minimum Oxygen Flow Requirements:

The knife valve (oxygen/cylinder gas) is designed to provide minimum oxygen flow continually (to prevent hypoxia due to not enough oxygen).

3. Oxygen Failure Alarms and Cut-off Devices:

If the oxygen supply level drops to a less-than-safe level, the Boyles Apparatus alarms and will cease to supply the anesthetic gases thereby limiting exposure to the patient.

4. Monitoring Devices: 

Currently, the basic Boyles Apparatus units, will now be available with modern monitoring devices that are less invasive to the patient and allow for earlier responses to less than ideal anesthetic management.

Maintenance Tips for Boyles Apparatus:

1. Inspect Before Each Use

Before Boyles apparatus is used, it must always be checked. Loose pipes, oxygen supply in order, operational gauges/flowmeters, etc. 

2. Wipe Breathing System After Each Use

After Boyles apparatus is used, the breathing system (which is the entire breathing circuit, face mask, reservoir bag and tubing) should be cleaned and disinfected so that it does not spread infection and to keep the functioning hygienic.

3. Check Vaporizers and Refill

Check and top up vaporizers levels as necessary and only refill with the correct anaesthetic agent. Arrange to have vaporizers check calibrated on a routine basis to ensure accurate delivery.

4. Change CO₂ Absorbent When Necessary

When the color changes or saturation occurs, it is time to change the CO₂ absorbent (for example: soda lime). Changing the absorbent correctly will recycle gas and reduce the accumulation of carbon dioxide. 

5. Routinely test the oxygen failure alarms

Get into the habit of testing the oxygen alarm system whenever Boyles apparatus is used. Oxygen failure alarms are essential for patient safety and need to work correctly every time.

Frequently Asked Questions:

What is Boyles Apparatus? 

Boyles Apparatus is a medical device designed to deliver a controlled mixture of oxygen and anesthetic gases to patients undergoing surgery. 

How much does a Boyles apparatus cost in India?

In India, Boyles apparatus price starts from ₹12,500 and it goes up to ₹1,45,000, depending on brands, models, and features.

How does Boyles Apparatus function? 

Boyles Apparatus uses compressed gases like oxygen and nitrous oxide, which pass through vaporizers where anesthetic agents are added. This mixture is then delivered to the patient through a breathing circuit, ensuring proper sedation and ventilation.

What are the key parts of Boyles Apparatus? 

Essential components of Boyles Apparatus include gas cylinders, pressure regulators, individual flow meters, vaporizers for anesthetic delivery, and a patient breathing system. 

Is Boyles Apparatus easy to operate? 

Yes, Boyles Apparatus is user-friendly, with clear dials, color-coded markings, and simple controls that guide both new and experienced users in monitoring gas flow and concentrations accurately.

Popular Categories:

Anesthesiology Equipment | Anesthesia Machine | Portable Anaesthesia Machine | Laryngoscope | Pediatric Laryngoscope | Video Laryngoscope | laryngoscope Blade | Anesthesia Ventilator | Guedel Airway | Anesthesia VaporizerECG Machine | Single Channel ECG Machine | 3 Channel ECG Machine | 6 Channel ECG Machine | 12 Channel ECG Machine | Ventilator Machine | ICU Ventilator | Oxygen Concentrator Machine | Portable Oxygen Concentrator | Home Oxygen Concentrator | Nebulizer Machine | ICU Ventilator | Dialysis Machine | DVT Pump | Defibrillator | AED Machine | Cardiac Monitor | Multipara Monitor | Pulse Oximeter | Patient Monitor | Fetal Monitor | BiPAP & CPAP Machine | Suction MachinePatient Warmer | Autoclave Machine | X Ray Machine | CR & DR System | Ultrasound Machine | MRI Machine | CT Scan Machine | Littmann Stethoscope | TMT Machine | Holter Monitor | Spirometer Machine | Audiometer | EMG Machine | EEG Machine | Stretcher | Hospital Chair | Hospital Beds | Hospital Trolley | Biochemistry Analyzer | CBC Machine | Centrifuge Machine | Urine Analyzer | Lab Shakers and Rotators | ESR Analyzer | Surgical Microscope | ECG Paper | Insulin Pump | Syringe PumpFeeding Pump | Oximeter | Stethoscope